Cardiac arrest in the perioperative period is associated with significant morbidity and mortality. Novel resuscitation devices may afford patients improved survival and limit neurologic injury. We report a case of cardiac arrest in the postanesthesia care unit that required an extensive period of cardiopulmonary resuscitation assisted by the ResQPOD impedance threshold device to optimize coronary perfusion and a LUCAS chest compression system to maintain optimal cardiopulmonary resuscitation while transporting the patient to the cardiac catheterization laboratory.