Αρχειοθήκη ιστολογίου

Παρασκευή 14 Δεκεμβρίου 2018

Mandated wrapping of airway cart instruments: Limited access without the intended safety benefits

Objectives/Hypothesis

Isolated case studies have shown improper sterilization or contamination of equipment from anesthesia carts can lead to transmission of disease and even death. Citing this literature, national accrediting agencies mandated all instruments in the otolaryngology airway carts at San Antonio Military Medical Center be packaged to prevent contamination. This study sought to determine the infection and safety implications of packaged airway cart instruments.

Study Design

Retrospective chart review.

Methods

A review of upper aerodigestive tract procedures, some of which penetrated mucosa, was performed by analyzing 100 patient records during the unpackaged period and 100 during the packaged period. A comparison of infections, deaths, and length of stay in the hospital was included in the analysis. Additionally, a timed simulation to setup a simple group of instruments for an emergency airway situation from both the unpackaged and packaged airway carts was performed using a total of 11 surgical technologists and nurses.

Results

Each group had a total of four airway infections and neither had any deaths. The average length of hospital stay was 0.36 days for the unpackaged period and 0.44 days from the packaged period. None of these variables reached statistical significance. The average time to find and set out the correct instruments for the two groups was 46.6 and 95.5 seconds for the unpackaged and packaged airway carts, respectively (P = .004).

Conclusions

This study suggests individually packaging of instruments used for emergency airway cases may put lives at risk when time matters and fails to decrease the risk of infection.

Level of Evidence

3 Laryngoscope, 2018



https://ift.tt/2Eukrlh

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου