Αρχειοθήκη ιστολογίου

Παρασκευή 17 Αυγούστου 2018

The Spider Limb Positioner in subscapular system free flaps

Publication date: October 2018

Source: Oral Oncology, Volume 85

Author(s): Jayne R. Stevens, Andrew J. Rosko, Emily Marchiano, Cate Haring, Steven B. Chinn, Kelly M. Malloy, Mark E. Prince, Keith Casper, Jeffrey Moyer, Douglas Chepeha, Chaz L. Stucken, Matthew E. Spector

Abstract
Background

The subscapular system is a versatile vascular network that can provide multiple flaps for reconstruction of the head and neck. A significant drawback of using the subscapular system is that patient positioning can preclude the use of simultaneous two-team ablative and reconstructive surgery. Herein, we describe a novel use of an upper extremity limb positioner (Spider Limb Positioner) used primarily in orthopedic surgery to facilitate concurrent two-team technique in head and neck surgery.

Methods

Using a bean bag and the Spider Limb Positioner for the upper extremity, a semidecubitus position was used for subscapular donor site dissection. Ablative and reconstructive teams worked concurrently in all cases.

Results

This technique was utilized 78 times on 73 patients, with chimeric flaps used in 38% of cases. The average operative time was 466 min. Only one patient required repositioning intraoperatively due to a change in the subscapular donor site side. There were no nerve compression injuries or positioning related complications.

Conclusion

Scapular and parascapular free flaps are useful tools for reconstruction of the head and neck. In a two-team approach, the use of a semidecubitus position in conjunction with the Spider Limb Positioner facilitates exposure for the reconstructive team without compromising access for the ablative team.