Αρχειοθήκη ιστολογίου

Σάββατο 8 Σεπτεμβρίου 2018

Perioperative Considerations for Evolving Artificial Pancreas Devices

Type 1 diabetes mellitus is a lifelong condition. It requires intensive patient involvement including frequent glucose measurements and subcutaneous insulin dosing to provide optimal glycemic control to decrease short- and long-term complications of diabetes mellitus without causing hypoglycemia. Variations in insulin pharmacokinetics and responsiveness over time in addition to illness, stress, and a myriad of other factors make ideal glucose control a challenge. Control-to-range and control-to-target artificial pancreas devices (closed-loop artificial pancreas devices [C-APDs]) consist of a continuous glucose monitor, response algorithm, and insulin delivery device that work together to automate much of the glycemic management for an individual while continually adjusting insulin dosing toward a glycemic target. In this way, a C-APD can improve glycemic control and decrease the rate of hypoglycemia. The MiniMed 670G (Medtronic, Fridley, MN) system is currently the only Food and Drug Administration–cleared C-APD in the United States. In this system, insulin delivery is continually adjusted to a glucose concentration, and the patient inputs meal-time information to modify insulin delivery as needed. Data thus far suggest improved glycemic control and decreased hypoglycemic events using the system, with decreased need for patient self-management. Thus, the anticipated use of these devices is likely to increase dramatically over time. There are limited case reports of safe intraoperative use of C-APDs, but the Food and Drug Administration has not cleared any device for such use. Nonetheless, C-APDs may offer an opportunity to improve patient safety and outcomes through enhanced intraoperative glycemic control. Anesthesiologists should become familiar with C-APD technology to help develop safe and effective protocols for their intraoperative use. We provide an overview of C-APDs and propose an introductory strategy for intraoperative study of these devices. Accepted for publication August 8, 2018. Funding: None. The authors declare no conflicts of interest. Reprints will not be available from the authors. Address correspondence to Micah T. Long, MD, Department of Anesthesiology, University of Wisconsin School of Medicine and Public Health, B6/319 UW CSC, 600 Highland Ave, Madison, WI 53792. Address e-mail to mtlong@wisc.edu. © 2018 International Anesthesia Research Society

https://ift.tt/2wT6Ttq

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου