Αρχειοθήκη ιστολογίου

Κυριακή 1 Ιουλίου 2018

A retrospective analysis of surgical resection of large ear keloids

Australasian Journal of Dermatology, EarlyView.


https://ift.tt/2lLCbgL

Histogram analysis of apparent diffusion coefficient maps for differentiating malignant from benign parotid gland tumors

Abstract

Purpose

To evaluate the diagnostic performance of histogram parameters derived from diffusion-weighted imaging (DWI) for differentiating malignant from benign parotid gland tumors compared with that of hotspot region of interest (ROI)-based apparent diffusion coefficient (ADC) measurement.

Methods

Our study retrospectively enrolled 60 patients with parotid gland tumors who had undergone DWI scan for pre-treatment evaluation. ADC measurements were performed using hotspot ROI (ADCHS-ROI)-based and histogram-based approach. Histogram parameters included mean (ADCmean), median (ADCmedian), 10th (ADC10), 90th (ADC90) percentiles, skewness and kurtosis of ADC. Mann–Whitney U test, Kruskal–Wallis test with post hoc Dunn–Bonferroni method and receiver operating characteristic (ROC) curve analyses were used for statistical analyses.

Results

ADCHS-ROI and ADC histogram parameters showed no significant differences between malignant and benign parotid gland tumors (All Ps > 0.05). Within the sub-group analyses, Warthin's tumors showed the lowest ADCHS-ROI, ADCmean, ADCmedian, ADC10 and ADC90 value, followed by malignant tumors and pleomorphic adenomas (All Ps < 0.05). ADC10 out-performed ADCHS-ROI in differentiating malignant tumors from pleomorphic adenomas (area under curve, 0.890 vs 0.821; sensitivity, 79.31 vs 82.76%; specificity, 90.91 vs 72.73%; P = 0.016), and improved the diagnostic performance in differentiating malignant tumors from Warthin's tumors (area under curve, 1.000 vs 0.965; sensitivity, 100.00 vs 90.91%), although the difference was not significant (P = 0.348).

Conclusions

ADC histogram analysis, especially ADC10, might be a promising imaging biomarker for characterizing parotid gland tumors.



https://ift.tt/2IJZlgn

Newborn Screening Saves Lives but Cannot Replace the Need for Clinical Vigilance

Newborn screening for cystic fibrosis (CF) enables early diagnosis and treatment leading to improved health outcomes for patients with CF. Although the sensitivity of newborn screening is high, false-negative results can still occur which can be misleading if clinicians are not aware of the clinical presentation of CF. We present a case of a young male with negative newborn screen diagnosed for CF. He was diagnosed at 3 years of age despite having symptoms indicative of CF since infancy. The delayed diagnosis resulted in diffuse lung damage and poor growth.

https://ift.tt/2IGodWw

Measuring Patient Knowledge of Kidney Transplantation: an Initial Step to Close the Knowledge Gap

No abstract available

https://ift.tt/2KxnOdU

Measurement Characteristics of the Knowledge Assessment of Renal Transplantation (KART)

Background Kidney transplant is the best treatment for most end-stage renal disease (ESRD) patients, but proportionally few ESRD patients receive kidney transplant. To make an informed choice about whether to pursue kidney transplant, patients must be knowledgeable of its risks and benefits. To reliably and validly measure ESRD patients' kidney transplant knowledge, rigorously tested measures are required. This paper describes the development and psychometric testing of the Knowledge Assessment of Renal Transplantation (KART). Methods We administered 17 transplant knowledge items to a sample of 1,294 ESRD patients. Item characteristics and scale scores were estimated using an item response theory (IRT) graded response model. Construct validity was tested by examining differences in scale scores between patients who had spent 1 hour receiving various types of transplant education. Results IRT modelling suggested that 15 items should be retained for the KART. This scale had a marginal reliability of 0.75 and evidenced acceptable reliability (>0.70) across most of its range. Construct validity was supported by the KART's ability to distinguish patients who had spent 1 hour receiving different types of kidney transplant education, including talking to doctors/medical staff [effect size (ES) = 0.61; p

https://ift.tt/2KEQZII

Efficient B-cell depletion with rituximab despite massive proteinuria

No abstract available

https://ift.tt/2KnFXvj

Comparison of two Luminex Single-Antigen bead flow cytometry assays for detection of Donor Specific Antibodies after renal transplantation

Background Defining the clinical relevance of Donor Specific HLA antibodies (DSA) detection by Luminex Single Antigen (LSA) flow beads assay is critical in monitoring posttransplant outcome. Methods Sera of kidney transplanted patients were tested by LSA1 and LSA2 with One Lambda Labscreen (test 1) and Immucor Lifecodes (test 2), at the time of a graft biopsy. The first group (G1, n=50) had a biopsy highly suggestive of humoral rejection and the second (G2, n=50) had no criteria of rejection. Positivity criteria for DSA was MFI >500 for test 1, while specificity assignation respected provider's recommendations for test 2. Results In G1, we identified at least 1 DSA in 44 patients with test 1, and in 39 patients with test 2. In G2, test 1 identified at least 1 DSA in 16 patients (32%) and test 2 in 7 patients (14 %). Sensitivity and specificity for ABMR diagnosis was 88% and 68% respectively with One Lambda, and 78% and 86% respectively with Immucor. Correlation and agreement were found in class I and II between intensity parameters of the 2 manufacturers. The use of the sum of the intensity of DSA (sDSA) improved the sensitivity and specificity of the 2 tests. Conclusions We report the first comparative study of the 2 Luminex assays available for detecting DSA in the post kidney transplant setting. Although there is a good correlation and reliability between the 2 assays, significant differences exist. Positivity criteria for DSA determination differ and interpretation should take these specificities into account. * Corresponding author: Dominique Bertrand, MD, Rouen University Hospital, 1 rue de Germont 76000 Rouen, France, dominique.bertrand@chu-rouen.fr Authorship: DB: performed research, collected data, analyzed data, and wrote the paper. FF, FHam, FHau: collected the data, performed research. DG: contributed to the revision and approval of the paper. All the others authors: collected data and contributed to the approval of the paper. Funding The authors have declared no funding. Disclosure: All of the authors of this manuscript have no conflicts of interest to disclose as described by Transplantation. Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.

https://ift.tt/2KDewdj