Αρχειοθήκη ιστολογίου

Παρασκευή 18 Δεκεμβρίου 2015

Cough Augmentation in Subjects With Duchenne Muscular Dystrophy: Comparison of Air Stacking via a Resuscitator Bag Versus Mechanical Ventilation

BACKGROUND:Air stacking improves cough effectiveness in people with Duchenne muscular dystrophy (DMD) and respiratory muscle weakness. However, it is not known whether air stacking is more effective via a resuscitator bag or a home ventilator.METHODS:This prospective randomized study investigated the effect of air stacking via a volume-cycled home ventilator versus via a resuscitator bag in participants with DMD. Maximum insufflation capacity and peak expiratory flow during spontaneous (cough peak flow) and air stacking-assisted cough maneuvers (air stacking-assisted cough peak flow) were measured.RESULTS:Fifty-two adult DMD subjects receiving noninvasive ventilation were included in the study: 27 participants performed air stacking via their home ventilator (home-ventilator group; age = 25.3 ± 5.1 y; forced vital capacity (FVC) = 809 ± 555 mL), and 25 participants used a resuscitator bag (resuscitator-bag group; age = 24.7 ± 5.7 y, FVC = 807 ± 495 mL). Following a single training session, air stacking could be performed successfully by 89% (home ventilator) and 88% (resuscitator bag) of participants. There were comparable maximum insufflation capacities (1,481 mL for the home-ventilator group vs 1,344 mL for the resuscitator-bag group, P = .33) and mean air stacking-assisted cough peak flow values (199 L/min for the home-ventilator group vs 186 L/min for the resuscitator-bag group, P = .33) between techniques. Air stacking-assisted cough peak flow increased significantly compared with baseline in both groups (mean increase: +51% [home ventilator] vs +49% [resuscitator bag], P < .001), with individual air stacking-assisted cough peak flow improvements ranging from −20 to 245%.CONCLUSIONS:Cough augmentation is an important component of the respiratory management of people with a neuromuscular disorder. No difference in cough effectiveness as measured by air stacking-assisted cough peak flow was found in air stacking via a ventilator compared with via a resuscitator bag. Both methods achieved mean air stacking-assisted cough peak flow values of >160 L/min. Provision of an inexpensive resuscitator bag can effectively improve cough capacity, and it is simple to use, which may improve access to respiratory care in people with DMD.

from #MedicinebyAlexandrosSfakianakis via xlomafota13 on Inoreader http://ift.tt/1ZfwFPK
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου