Publication date: Available online 8 April 2016
Source:American Journal of Infection Control
Author(s): Laura Arelí Sánchez-Carrillo, Juan Manuel Rodríguez-López, Dionisio Ángel Galarza-Delgado, Laura Baena-Trejo, Magaly Padilla-Orozco, Lidia Mendoza-Flores, Adrián Camacho-Ortiz
BackgroundThe importance of hand hygiene in the prevention of health care–associated infection is well known. Experience with hand hygiene compliance (HHC) evaluation in hemodialysis units is scarce.MethodsThis study was a 3-phase, prospective longitudinal intervention study during a 5-month period in a 13-bed hemodialysis unit at a university hospital in Northern Mexico. The unit performs an average of 1,150 hemodialysis procedures per month. Compliance was evaluated by a direct observer and a video assisted observer. Feedback was given to health care workers in the form of educational sessions and confidential reports and video analysis of compliance and noncompliance.ResultsA total of 5,402 hand hygiene opportunities were registered; 5,201 during 7,820 minutes of video footage and 201 by direct observation during 1,180 minutes. Lower compliance during the baseline evaluation was observed by video monitoring compared with direct observation (P <0.05). Discrepancy between both methods was 29.2% (0.4%-59.8%); the average improvement in compliance during the study was 30.6% (range, 7.3%-75.5%). Global and Individual results for each subject revealed a statistically significant Improvement in the majority. Noncompliance according to WHO's 5 Moments for HH was greater for moment 5 (30.1%). We estimated that a health care worker in a hemodialysis unit could take 22-44.3% of working hours for proper hand hygiene compliance.ConclusionsVideo-assisted monitoring of hand hygiene is an excellent method for the evaluation of HHC in a hemodialysis unit; enhanced HHC can be achieved through a feedback program to the hemodialysis staff that includes video examples and confidential reports.
from #MedicinebyAlexandrosSfakianakis via xlomafota13 on Inoreader http://ift.tt/1Yl1Bg3
via IFTTT
Αρχειοθήκη ιστολογίου
-
►
2020
(289)
- ► Φεβρουαρίου (28)
-
►
2019
(9071)
- ► Δεκεμβρίου (19)
- ► Σεπτεμβρίου (54)
- ► Φεβρουαρίου (3642)
- ► Ιανουαρίου (3200)
-
►
2018
(39872)
- ► Δεκεμβρίου (3318)
- ► Σεπτεμβρίου (3683)
- ► Φεβρουαρίου (2693)
- ► Ιανουαρίου (3198)
-
►
2017
(41099)
- ► Δεκεμβρίου (3127)
- ► Σεπτεμβρίου (2173)
-
▼
2016
(13807)
- ► Δεκεμβρίου (700)
- ► Σεπτεμβρίου (600)
-
▼
Απριλίου
(1300)
-
▼
Απρ 09
(50)
- A Call to Formalize Training in Tobacco Dependence...
- Teaching at the Bedside. Maximal Impact in Minimal...
- Medical Education at the American Thoracic Society...
- Raising the Profile of Pulmonary Education for Phy...
- The Impact of Resident Training on Communication w...
- Adverse Events and Near-Misses Relating to Intensi...
- Development of a Tool to Assess Basic Competency i...
- A Letter to Prospective and Emerging Clinician Edu...
- Simulation Testing for Selection of Critical Care ...
- Variability in Lung Transplant Education during Pu...
- In vitro performance of two-piece zirconia implant...
- Dental adhesives and strategies for displacement o...
- Novel hydroxyapatite nanorods improve anti-caries ...
- Poststroke Aphasia Frequency, Recovery, and Outcom...
- Men and Women Demonstrate Differences in Early Fun...
- Patient with a Hook of the Hamate Fracture Present...
- Current Controversies in Thrombolytic Use in Acute...
- Preventative Care in the Patient with Inflammatory...
- Contents
- Double spinal cord lesions and pelvic floor electr...
- Editorial Board
- Pelvic floor electrophysiology in spinal cord injury
- FGFR1 N546K and H3F3A K27M mutation in a diffuse l...
- Editorial board
- Le robot en chirurgie thoracique : pour ou contre ?
- The Association of Changes in Sedentary Behavior o...
- Prevalence of Depressive Disorders in Children wit...
- Estudio prospectivo de la evolución del acúfeno tr...
- Hallazgo intraoperatorio, de nervio laríngeo infer...
- Manejo práctico de fugas periprótesis en pacientes...
- Lecanicillium longisporum on Cabbage Aphid ( Brevi...
- The role of mechanical pressure difference in the ...
- Pools of programmed death-ligand within the oral c...
- Association of the upregulated expression of focal...
- Successful intraoperative electrophysiologic monit...
- Brachytherapy after salvage surgery in cases with ...
- Prognostic value of FDG-PET volumetric parameters ...
- Historical compliance rates for providing postoper...
- Enhancement of hand hygiene compliance among healt...
- Anchored pseudo-de novo assembly of human genomes ...
- Allergen Immunotherapy: No Evidence of Infectious ...
- Reply
- Systemic B-cell abnormalities in patients with ato...
- Respiratory Syncytial Virus Infection Activates IL...
- Oral vinorelbine in combination with trastuzumab a...
- Power Spectral Density Analysis of Electrodermal A...
- An Experimental and Numerical Investigation of CO ...
- “It is by anatomy only that we can arrive at the k...
- Erratum to: Spectrum of MRI features of ganglion a...
- Late cardiac effects of chemotherapy in breast can...
-
▼
Απρ 09
(50)
- ► Φεβρουαρίου (1350)
- ► Ιανουαρίου (1400)
-
►
2015
(1500)
- ► Δεκεμβρίου (1450)
Ετικέτες
Σάββατο 9 Απριλίου 2016
Enhancement of hand hygiene compliance among health care workers from a hemodialysis unit using video-monitoring feedback
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου